Neuroelectrics® Instrument Controller (NIC) software application has been recreated, and NIC2.0 is the final result. With a new and modern interface, NIC2.0 provides the best experience to interact with Neuroelectrics® devices. NIC2.0 guarantees both reliable EEG monitoring experiments and safe brain stimulation treatments. NIC2.0 allows for both wireless and wired connections, depending on the device model. NIC2.0 is equipped with real-time EEG analysis tools and with advanced options for current controlled stimulation. NIC 2.0 is both Windows and Mac compatible.

FREE download here!.

NIC2.0 Protocol

NIC2.0 Liveview

Features

EEG Data
Real-time streaming and recording of multi-channel EEG data
Real-time filtering and visualization of EEG bands
Line noise filtering at 50 or 60 Hz
Tri-axial accelerometric data appended to EEG files
EEG time-frequency analysis
Real-time Power Spectrum Density (PSD) plots, with configurable temporal windows
Real-time Spectrogram visualization
Power bar band or power ratio representation
Scalp and cortical (upcoming) maps with power distribution display
Customized workspaces for EEG analysis
Stimulation
Multi-step protocols for stimulation
Multi-electrode montages with upt to 32 channels
Basic and advances modes with tDCS, tACS and tRNS
EEG monitoring during stimulation
Sham and double blind modes for clinical studies
Customized waveforms for stimulation currents (upcoming)
3D Modelling with Stim Preview
Finite Element Method (FEM) modelling incorporated in the software to simulate electric field distribution
Visualization of the electric field generated by tCS
Simulation of the electric field in the white or grey matter interfaces
Display of the potential, electric field magnitude and electric field components (tangential or orthogonal to cortical surface)
Single and double hemisphere views with medial cortex visualization
Electric field value visualization for chosen Automated Anatomical Labeling (AAL) cortical regions
Third-party interaction
Lab Streaming Layer (LSL) protocol for event synchronization (jitter: 2 ms)
TCP/IP data streaming
Raw EEG and triaxial accelerometric data streaming via TCP/IP or LSL
Send and receive triggers via TCP/IP or LSL
File formats: plain text (ASCII), and EDF+ or NEDF (binary)

Technical Specifications

NIC 2.0 is a redesigned platform that allows:
Control of multi-channel data transmission (EEG and Stimulation)
Real-time visualization of EEG features
Set-up the stimulation montage and parameters
Wireless device pairing, and wired connection options
Holter mode activation for SD card data storage
Single and double blinded features
Compatible with Windows and Mac OS X