NE008

STARSTIM R32

Starstim R32 is the ideal multi-channel neurostimulator for research studies that required the combination of tDCS, tACS, or tRNS with simultaneous EEG. Starstim R32 is perfect for closed loop stimulation experiments derived from EEG measurements. The Starstim system allows multiple electrode montages that can be arranged to target specific brain networks with multi-focal targets. In addition, when coupled with Stimweaver-P, Starstim offers a personalized service that allows one individual brain to be segmented and the stimulation target to be iteratively adjusted. The design of Starstim R32 represents a whole new concept. The headset has been totally redesigned to revolutionize the way to interact with the human brain. The new neoprene cap and its lacing system offer more comfort and precision to the system. The system can be adjustable to different head sizes, and the design is compatible with standard headphones. Furthermore, the Neuroelectrics software interface has been completely redesigned, too. Now, NIC 2.0 offers a brighter interface with many tools that can be easily arranged according to the preferences of the operator.

Be the first to conduct studies with 32 stimulation channels! (see publications with Starstim 8)

Technical Specifications

EEG functionality
Number of channels: (up to) 32
Sampling rate: 500 SPS
Bandwidth: 0 to 125 Hz (DC coupled)
Resolution: 24 bits – 0,05 µV resolution
Noise: < 1 µV RMS
Common mode rejection ratio: -115 dB
Input impedance: 1 GΩ
Stimulation functionality
Number of channels: (up to) 32
Sampling rate: 1000 SPS
Stimulation types: tDCS, tACS and tRNS
Customized waveform
Frequency range: 0-250 Hz (tACS); 0-500 Hz (tRNS)
Configurable bandpass filter for tRNS
Maximum current per channel: ± 4mA
Current accuracy: 1%
Current resolution: 1 μA
Current is configurable independently for each channel
Configurable Ramp-up and Ramp-down times
Voltage: ± 15 V per electrode (30 V potential difference)
Sham and Double blind modes available
Stimulation safety:
Max current per electrode: 2 mA
Max total injected current (by all electrodes, any time): 4 mA
Max duration per session: 1 hour
Stimulation session must be pre-programmed
Impedance check before and during stimulation
Abort functionality: possible at anytime
NECBOX (Neuroelectrics Control Box)
Battery: USB rechargeable Li-Ion battery
Battery operating time: 8 hours (combined EEG/tCS)
Data transmisstion: wireless (wi-fi network) or wired (USB cable)
microSD card slot (for offline data storage)
Output: EDF+, ASCII data files or TCP/IP raw data streaming
Accelerometer data recording: tri-axial @ 100 SPS

Product content

STARSTIM R32 [NE008]:
1 x [NE012S32] STARSTIM 32 NECBOX
1 x [NE017-32] SET OF CABLES STARSTIM 32
1 x [NE013] POWER ADAPTER
1 x [NE014] CURVED SYRINGE
1 x [NE015] USB STICK WITH MANUALS & [NE001SW] NIC SW
1 x [NE016a] ELECTRODE GEL 60CL
1 x [NE056-M] SS2032 HEADCAP SIZE M
50 x [NE025] STICKTRODE
4 x [NE026a] SPONSTIM 25
8 x [NE026b] SPONSTIM 8
32 x [NE029] NG PISTIM
32 x [NE032] NG GELTRODE
1 x [NE031b] USB WIFI DONGLE
1 x [NE033] SALINE SOLUTION 100ML
1 x [NE038S32] TESTBOARD HEAD
4 x [NE039] TESTBOARD CABLE
1 x [NE164] USB ISOLATOR & CABLE
Cookie policy: