Interacting with NIC

From Neuroelectric's Wiki
Revision as of 16:16, 25 October 2013 by Javier.acedo (talk | contribs) (Sending Markers to NIC from other software or hardware)
Jump to: navigation, search

In this page we describe how you can interact with NIC (Neuroelectrics Instrument Controller, the software for control with NE devices) using other software.

About Synchronization: general principles

Sending Markers to NIC from other software or hardware

NIC provides a server that other software can connect to in order to receive markers. Those received markers are synchronized with the EEG streaming for further analysis.

This NIC server is running in the TCP/IP port 1234. Up to five clients can simultaneously send markers to NIC by making a TCP/IP connection to this port.

Once a client is connected it needs to send the following string in order to send a marker:

<TRIGGER>XXXX</TRIGGER>

Where XXXX can represent any integer number different from zero (from -2147483647 to +2147483647). This marker will be co-registered in the output files generated by NIC to the corresponding EEG sample. For instance, in the output tabulated text file, there is a column just after the timestamp that is filled with zeros. When a marker is received its corresponding number is set to that column.

...
26748	-27675	35631	42398	532666	64345	12376	40988	0	1382432459788
26865	-26683	35685	42450	532711	64821	12376	41046	0	1382432459790
26810	-26821	35531	41997	532821	64945	13164	41099	0	1382432459792
26749	-26995	35325	42008	532712	64377	13478	41286	0	1382432459794
26796	-27245	35932	42391	532923	64245	13620	41117	300	1382432459796  <-- Reception of the marker #300
26622	-27510	35501	42630	532876	64193	13031	40986	0	1382432459798
26751	-27912	35611	42003	532345	64344	12967	40731	0	1382432459800
...


Receiving data streams from NIC using TCP/IP

Controlling NIC with Matlab: the MatNIC toolkit