Difference between revisions of "NIC2.0"

From Neuroelectric's Wiki
Jump to: navigation, search
m
 
(91 intermediate revisions by 3 users not shown)
Line 1: Line 1:
'''[http://www.neuroelectrics.com/products/software/nic2/ NIC2.0 ]''' is the new and redesigned version of the former Neuroelectrics Instrument Controller (NIC) application.
+
==NIC2 software==
  
With a modern and intuitive interface, NIC2.0 allows computers to interact and control Neuroelectrics devices, such as [http://www.neuroelectrics.com/products/enobio/enobio-8/ Enobio 8] and [http://www.neuroelectrics.com/products/starstim/starstim-32/ Starstim 32]. NIC2.0 is equipped with basic and advanced modes to design and monitor any experiment involving electroencephalography (EEG) and/or non invasive brain stimulation with transcranial current stimulation (tCS).
 
  
NIC2.0 is compatible with both Windows and Mac OS computers. Use the following hyperlinks to have access to the NIC User Manual and respective installation files:
+
'''[http://www.neuroelectrics.com/products/software/nic2/ NIC2.0 ]'''  is the new and redesigned version of the former '''Neuroelectrics Instrument Controller (NIC)''' application.
  
[http://www.neuroelectrics.com/download/NE_UM_Part03_NIC2.pdf '''NIC User Manual v2.0'''] </p>
+
With a modern and intuitive interface, NIC2 allows computers to interact and control Neuroelectrics devices, such as [http://www.neuroelectrics.com/products/enobio/ Enobio ] and [http://www.neuroelectrics.com/products/starstim/ Starstim]. NIC2 is equipped with basic and advanced modes to design and monitor any experiment involving electroencephalography (EEG) and/or non-invasive brain stimulation with transcranial current stimulation (tCS).
[http://www.neuroelectrics.com/downloads/ '''NIC2.0 Installation Files''']
 
  
NIC2.0 is not compatible with out-dated devices. Check the firmware version of your device and proceed accordingly:
+
                  [[File:NIC2.0.PNG|500px]]
  
<p>
+
== Features ==
• Firmware greater or equal to 1.2.51:
 
Your device requires no upgrade – it is fully compatible with NIC2.0. Download NIC2.0 and start using it!
 
</p>
 
  
Firmware inferior to 1.2.51, and greater or equal to 1.2.30:
+
'''EEG Data'''
Your device requires a firmware update to become compatible with NIC2.0. Such update can be remotely performed.
 
Contact NE Support (support(at)neuroelectrics.com) to schedule a session to remotely update your device.
 
</p>
 
  
• Firmware inferior to 1.2.30, and greater or equal to 1.2.07:
+
-Real-time streaming and recording of multi-channel EEG data
Your device requires a firmware update to become compatible with NIC2.0 Such update must be done at Neuroelectrics manufacturing site.
 
Contact NE Support (support(at)neuroelectrics.com) to manage the device shipment and upgrade process.
 
</p>
 
  
• Firmware inferior to 1.2.07:
+
-Real-time filtering and visualization of EEG bands
The device hardware must be upgraded to become compatible with NIC2.0.
+
 
Contact NE Sales (sales(at)neuroelectrics.com) to request a device upgrade.
+
-Line noise filtering at 50 or 60 Hz
 +
 
 +
-Tri-axial accelerometric data appended to EEG files
 +
 
 +
• '''EEG time-frequency analysis'''
 +
 
 +
-Real-time Power Spectrum Density (PSD) plots, with configurable temporal windows
 +
 
 +
-Real-time Spectrogram visualization
 +
 
 +
-Power bar band or power ratio representation
 +
 
 +
-Scalp and cortical (upcoming) maps with power distribution display
 +
 
 +
-Customized workspaces for EEG analysis
 +
 
 +
• '''Stimulation'''
 +
 
 +
-Multi-step protocols for stimulation
 +
 
 +
-Multi-electrode montages with upt to 32 channels
 +
 
 +
-Basic and advances modes with tDCS, tACS and tRNS
 +
 
 +
-EEG monitoring during stimulation
 +
 
 +
-Sham and double blind modes for clinical studies
 +
 
 +
-Customized waveforms for stimulation currents (upcoming)
 +
 
 +
• '''3D Modelling with Stim Preview'''
 +
 
 +
-Finite Element Method (FEM) modelling incorporated in the software to simulate electric field distribution
 +
 
 +
-Visualization of the electric field generated by tCS
 +
 
 +
-Simulation of the electric field in the white or grey matter interfaces
 +
 
 +
-Display of the potential, electric field magnitude and electric field components (tangential or orthogonal to cortical surface)
 +
 
 +
-Single and double hemisphere views with medial cortex visualization
 +
 
 +
-Electric field value visualization for chosen Automated Anatomical Labeling (AAL) cortical regions
 +
 
 +
• '''Third-party interaction'''
 +
 
 +
-Lab Streaming Layer (LSL) protocol for event synchronization (jitter: 2 ms)
 +
 
 +
-TCP/IP data streaming
 +
 
 +
-Raw EEG and triaxial accelerometric data streaming via TCP/IP or LSL
 +
 
 +
-Send and receive triggers via TCP/IP or LSL
 +
 
 +
-File formats: plain text (ASCII), and EDF+ or NEDF (binary)
 +
 
 +
== Technical specifications: ==
 +
 
 +
NIC 2 is a redesigned platform that allows:
 +
 
 +
-Control of multi-channel data transmission (EEG and Stimulation)
 +
 
 +
-Real-time visualization of EEG features
 +
 
 +
-Set-up the stimulation montage and parameters
 +
 
 +
-Wireless device pairing, and wired connection options
 +
 
 +
-Holter mode activation for SD card data storage
 +
 
 +
-Single and double blinded features
 +
 
 +
-Compatible with Windows and Mac OS X
 +
 
 +
== Device compatibility ==
 +
 
 +
NIC2 is intended to be used only with Neuroelectrics® devices. The 5G devices, with WiFi™ and/or USB connection, are all compatible with NIC2.0.
 +
 
 +
NIC2 is not compatible with out-dated Bluetooth® devices. Check the firmware version of your device and proceed accordingly:
 +
 
 +
The firmware version is displayed in NIC when connecting the device with the software.
 +
 
 +
• '''Firmware greater or equal to 1.2.51''':
 +
It is fully compatible with NIC2.0.
 +
[https://www.neuroelectrics.com/download/NIC_2.0.11_Setup.exe] NIC2.0 and start using it!
 +
 
 +
'''Firmware inferior to 1.2.51''':
 +
Your device is not compatible with NIC2.0. If you are interested to use this software, contact sales for more information:
 +
sales@neuroelectrics.com
 +
 
 +
For Starstim 20/32 below FW version 3.0.20 if you want to upgrade the firmware to 3.0.26, the device hardware must be upgraded to become compatible. Contact NE Sales – ''sales(at)neuroelectrics.com'' – to request a device upgrade.
 +
 
 +
== System requirements ==
 +
 
 +
NIC2.0 is compatible with both Windows and Mac OS computers.
 +
The computer used to install NIC2.0 needs to have the following system requirements:
 +
 
 +
• Processor: 1.6 GHz
 +
 
 +
• RAM: 2 GB
 +
 
 +
• Interfaces: USB, WiFi and/or Bluetooth® (3.0 or 2.1)
 +
 
 +
• Screen resolution: 1280 x 768
 +
 
 +
== Manual & Download ==
 +
 
 +
Use the following hyperlinks to have access to the NIC User Manual and respective installation files:
 +
 
 +
• [https://www.neuroelectrics.com/documentation/ '''NIC2.0 User Manual v2.0''']
 +
 
 +
• [http://www.neuroelectrics.com/downloads/ '''NIC2.0 Installation Files'''] for MAC and Windows
 +
 
 +
== Mailing List ==
 +
 
 +
When downloading NIC2, you are asked to fill in a short form with basic information (name, email, affiliation and country). Such contact data are stored in Neuroelectrics® database and added to NIC mailing list.
 +
As a member of the NIC mailing list, you will be informed each time there is a new version of NIC and respective changes and/or improvements.

Latest revision as of 14:13, 3 July 2019

NIC2 software

NIC2.0 is the new and redesigned version of the former Neuroelectrics Instrument Controller (NIC) application.

With a modern and intuitive interface, NIC2 allows computers to interact and control Neuroelectrics devices, such as Enobio and Starstim. NIC2 is equipped with basic and advanced modes to design and monitor any experiment involving electroencephalography (EEG) and/or non-invasive brain stimulation with transcranial current stimulation (tCS).

                  NIC2.0.PNG

Features

EEG Data

-Real-time streaming and recording of multi-channel EEG data

-Real-time filtering and visualization of EEG bands

-Line noise filtering at 50 or 60 Hz

-Tri-axial accelerometric data appended to EEG files

EEG time-frequency analysis

-Real-time Power Spectrum Density (PSD) plots, with configurable temporal windows

-Real-time Spectrogram visualization

-Power bar band or power ratio representation

-Scalp and cortical (upcoming) maps with power distribution display

-Customized workspaces for EEG analysis

Stimulation

-Multi-step protocols for stimulation

-Multi-electrode montages with upt to 32 channels

-Basic and advances modes with tDCS, tACS and tRNS

-EEG monitoring during stimulation

-Sham and double blind modes for clinical studies

-Customized waveforms for stimulation currents (upcoming)

3D Modelling with Stim Preview

-Finite Element Method (FEM) modelling incorporated in the software to simulate electric field distribution

-Visualization of the electric field generated by tCS

-Simulation of the electric field in the white or grey matter interfaces

-Display of the potential, electric field magnitude and electric field components (tangential or orthogonal to cortical surface)

-Single and double hemisphere views with medial cortex visualization

-Electric field value visualization for chosen Automated Anatomical Labeling (AAL) cortical regions

Third-party interaction

-Lab Streaming Layer (LSL) protocol for event synchronization (jitter: 2 ms)

-TCP/IP data streaming

-Raw EEG and triaxial accelerometric data streaming via TCP/IP or LSL

-Send and receive triggers via TCP/IP or LSL

-File formats: plain text (ASCII), and EDF+ or NEDF (binary)

Technical specifications:

NIC 2 is a redesigned platform that allows:

-Control of multi-channel data transmission (EEG and Stimulation)

-Real-time visualization of EEG features

-Set-up the stimulation montage and parameters

-Wireless device pairing, and wired connection options

-Holter mode activation for SD card data storage

-Single and double blinded features

-Compatible with Windows and Mac OS X

Device compatibility

NIC2 is intended to be used only with Neuroelectrics® devices. The 5G devices, with WiFi™ and/or USB connection, are all compatible with NIC2.0.

NIC2 is not compatible with out-dated Bluetooth® devices. Check the firmware version of your device and proceed accordingly:

The firmware version is displayed in NIC when connecting the device with the software.

Firmware greater or equal to 1.2.51: It is fully compatible with NIC2.0. [1] NIC2.0 and start using it!

Firmware inferior to 1.2.51: Your device is not compatible with NIC2.0. If you are interested to use this software, contact sales for more information: sales@neuroelectrics.com

For Starstim 20/32 below FW version 3.0.20 if you want to upgrade the firmware to 3.0.26, the device hardware must be upgraded to become compatible. Contact NE Sales – sales(at)neuroelectrics.com – to request a device upgrade.

System requirements

NIC2.0 is compatible with both Windows and Mac OS computers. The computer used to install NIC2.0 needs to have the following system requirements:

• Processor: 1.6 GHz

• RAM: 2 GB

• Interfaces: USB, WiFi and/or Bluetooth® (3.0 or 2.1)

• Screen resolution: 1280 x 768

Manual & Download

Use the following hyperlinks to have access to the NIC User Manual and respective installation files:

NIC2.0 User Manual v2.0

NIC2.0 Installation Files for MAC and Windows

Mailing List

When downloading NIC2, you are asked to fill in a short form with basic information (name, email, affiliation and country). Such contact data are stored in Neuroelectrics® database and added to NIC mailing list. As a member of the NIC mailing list, you will be informed each time there is a new version of NIC and respective changes and/or improvements.